An electric hydraulic torque wrench pump is the power heart of any bolting operation. Whether you are commissioning a new unit or putting one back into service after storage, running a structured test before production is the only way to protect personnel, bolts, flanges and the pump itself. In this guide we walk through the pre-use testing routine and correct operating procedure for the Galaxy WP Series (WPT25) electric hydraulic torque wrench pump, rated at 700 bar (70 MPa) maximum working pressure, with a 1.1 kW brushless motor and a 6 L oil reservoir.
1. Why testing before use is non-negotiable
A torque wrench pump converts electrical energy into hydraulic pressure that can reach 700 bar. A blocked vent, a loose high-pressure hose, contaminated oil or an uncalibrated gauge can turn a controlled bolting job into a dangerous over-torque event. The WP Series already ships with built-in safeguards - one-minute idle auto shut-off, automatic decompression after stop, and electronic overload protection - but these features only work when the mechanical and hydraulic sides are in good condition. Always run the following bench test before connecting the wrench.
2. Pre-use inspection (visual and mechanical)
Before energising the unit, confirm the following on the pump itself:
Oil level. The tank holds 6 L of hydraulic oil. Check the sight glass; the oil must sit between the MIN and MAX marks. Running the pump low draws in air and produces spongy, inaccurate pressure.
Oil condition. Look for milky appearance (water contamination), metal particles on the dipstick, or a burnt smell. If any is present, drain and refill before testing.
High-pressure hoses and couplings. Inspect the NPT 1/4 outlet and both hoses for cracks, bulges, crushed sections or crushed couplings. Hand-tighten and then wrench-tighten every connection; loose fittings under 700 bar spray oil.
Pressure gauge. The gauge must point to zero at rest. If the needle is stuck or off-zero, recalibrate or replace it before taking any reading as "true torque".
Remote pendant / foot switch. Press the advance button and listen for the solenoid click. The cable must be free of cuts, and the yellow start guard clean.
Cooling fan and heat sink. Make sure the external fan spins freely and the heat-sink fins are not clogged with dust, which would trigger thermal shutdown on long jobs.
Power supply. The WPT25 runs on 220 V / 50 Hz single phase. Confirm the voltage matches the site supply; running it on wrong voltage damages the brushless motor and the PCB controller.
3. Bench pressure test (without the wrench connected)
This is the core functional test. Do it with the pump anchored on a firm, level surface.
Close the pressure relief / directional valve to the holding (advance) position.
Switch on the main power. The controller should energise without fault light.
Press and hold the advance button on the pendant. The pump should start on the low-pressure (high-flow) stage and pressure should begin to rise.
Watch the gauge climb. On the WPT25 the three-stage flow is 8 L/min at low pressure (7 MPa), 1.7 L/min at mid pressure (28 MPa), stepping down to 0.85 L/min at high pressure (70 MPa) - you should feel the stroke slow naturally as pressure builds, not jam abruptly.
Bring the gauge up to 50–60% of rated pressure (around 350–420 bar) and hold for 30 seconds. The needle must stay stable within ±1 bar; a slow drop indicates valve or seal wear.
Now raise it to 700 bar briefly (a few seconds only, not sustained) and confirm the overload protection trips cleanly if you exceed it.
Release the advance button. The pump must auto-decompress - the gauge should fall back toward zero within a few seconds. If it does not, stop and inspect the unloading valve.
Leave the unit idle for one minute. The PCB should automatically cut power. This confirms the idle shut-off is alive.
If any of the eight steps fails, do not connect the wrench. Tag the pump out and service it.
4. Correct operating procedure on the job
Once the bench test passes, follow this sequence when connecting an actual hydraulic torque wrench:
Mount the wrench squarely on the nut, with the reaction arm seated firmly against a solid stop (adjacent nut, washer or machined surface). Never let the reaction arm "float" - it carries the full reaction torque.
Bleed air from the wrench. With the pump at low pressure, cycle the wrench advance/retract two or three times at ~100 bar until movement is smooth and no hissing is heard.
Set target pressure on the pump's pressure control valve using the wrench manufacturer's torque–pressure chart. Never rely on memory; every wrench model has its own curve.
Press advance. The WP Series auto-cycle feature lets you hold the button once and the wrench will keep cycling until the nut reaches target pressure - this is the main productivity advantage over a two-stage pump, but do not leave the station unattended.
Hold at target pressure for the recommended dwell time (typically 3–5 seconds) so the bolt stretch settles, then release.
Retract and reposition the wrench for the next nut. Work flange bolt circles in a criss-cross pattern in 30–50% increments to achieve uniform bolt load.
At the end of the shift, lower pressure to zero, disconnect power, and relieve all residual pressure before breaking any coupling.
5. Common mistakes that shorten pump life
Overtorquing above 700 bar - blows seals and distorts the pump head.
Skipping the air-bleed step - causes inaccurate readings and can crack a wrench cylinder.
Running with low oil - cavitation eats the pump head and the ceramic plungers.
Ignoring the cooling fan - continuous-operation jobs need the external heat sink; block it and the PCB will thermal-shutdown mid-flange.
Mixing hydraulic oils - use a good-grade anti-wear hydraulic oil (ISO VG 32 or 46 depending on ambient temperature). Never use engine or transmission oil.
Leaving hoses under pressure overnight - always decompress after the job; the auto-decompression function only triggers on stop, so confirm the gauge is at zero before leaving site.
6. Routine maintenance schedule
Every 40 working hours: check oil level, clean the suction strainer, inspect hose fittings.
Every 3 months or 500 hours: change the hydraulic oil and replace the return filter.
Every 6 months: recalibrate the pressure gauge against a dead-weight tester or reference gauge.
Annually: inspect the brushless motor brushes (where accessible), test the overload trip, and verify the one-minute idle shut-off.
7. About the Galaxy WP Series
The WPT25 electric hydraulic torque wrench pump is built for continuous bolting work in steel mills, wind farms, pipeline flanges and heavy equipment assembly. Its three-stage pump head delivers roughly 50% higher speed than a conventional two-stage pump, while the optimised PCB controller handles idle shut-off, auto decompression and overload protection. The unit weighs just 28 kg and measures 410 × 320 × 480 mm, so it can be moved between flanges by one operator.
For datasheets, torque–pressure conversion charts or a quotation on the WPT25 and full WP Series range, contact the Galaxy Machinery sales team at kathy.yan@galaxy-machinery.com.